Px24500 dmx-driver

 Retail

 9 views
of 8
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Description
The PX24500 DMX Driver allows you to connect your RGB LED Lights, LED Lighting, LED Ribbon strips or RGB LED Modules to DMX512 or DMX1990 Lighting controllers. Then by using PWM & DMX, you can change the color and dimming of your RGB LED lights. For 12 to 24VDC systems only. Includes one 6' Cat5 cable with RJ45 jack connectors.
Share
Transcript
  • 1. With advanced micro-computer control technology, PX series convert the widely used DMX512/1990 signal to analog signal. Can choose 1~3 output channel, 256-level brightness control. For connecting of light console and analog device, or lighting&building lamps controlling. FEATHERS - Meets DMX512/1990 - 256-level brightness, full-color control - 3 output CH., can drive 5A (Each CH.) - With control system, can express perfect effect - Can drive 1~3 channel of each lamp - Can set the DMX address freely - Modularizing, can be combined with LED module neatly - Can be custom-made DMX decoder PX24500 WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 2. TECH. CHARACTERISTICS Decode CH.: 1~3 Input Signal: DMX-512/1990 digital signal Output Signal: 0~24V PWM signal, can drive 5A(Each CH.) Power Supply: DC,+12~24V Power Dis.: <1W Power Output: 180W 12V/360W 24V Operating Temp.: 0~70℃ Size: 175(mm)*45(mm)*35(mm),can be custom-made Weight: ≤300g DIMENSION Internal Block Diagram WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 3. Appearance (1) DMX signal input interface (RJ11) (2) DMX signal output interface (RJ11) (3) Address setting interface (4) Driver output interface (5) Power input interface Interface Introduction DMX signal interface - Address setting interface Please find the detailed instruction for Address setting at Page 5. - Power input interface DC 12-25V input, supply power for decoder and the lamps it takes. - Driver output interface Common anode, V+ and R,G,B interface,can drive kinds of RGB module or single-color module, Can regulate output current according to the actual load. Remark: Connect the anode and RGB wire of common anode RGB module to the output interface of decoder directly; Connect the anode wire of single-color module to V+ on decoder, and connect the cathode wire 1 2 3 4 5 WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 4. to one of RGB pin according to the LED's color; Connect several colors single-color module to one decoder, please connect their anode wires to V+ pin on decoder. How to use PX24500 is controlled by DMX-512 digital signal。The frontage is DMX512 transmitter, take EC-DMX512 for example, to control 0~24V analog devices. We suppose to drive LED to introduce it. The connecting is below: TYPICAL APPLICATIONS - Circuit Diagram 1 WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 5. Connecting of DMX-512 Signal - The wire for DMX signal is STP,the DMX signal has positive and negative signal. Pay attention to the polarity while soldering. Connect the positive signal, negative signal and GND to the corresponding signal of PX24500. - Connect a signal terminal at the end of the whole connection. Calculate the power This product has a wide input/output voltage (DC 6-25V),it's rating current is 5A,so the rating power is different in different input, for example: Rating power in 12V:12V X 5A X 3 = 180 W Rating power in 24V:24V X 5A X 3 = 360 W DMX-512 Address Setting The DIP switch on PX24500 can set the binary value of the DMX512 address to receive data. The correlative bits is the 1-9 bits of the DIP switch, the 1st bit is LSB, the 9th bit MSB 512 addresses totally. The start address is the no. of the first channel of the decoder, the second channel will receive the data of start addess+1, and the third channel will receive the data of start addess+2.There are two way to find out the relation between the DIP switch and DMX address. calculational method: calculational formula:[The sum of 1~9 bit of the DIP switch] + 1 = DMX start address Set the n(th) bit of the DIP switch up(set to“1”)to get the value of such bit; Set the n(th) bit of the DIP switch down “0”),so the value of this bit is 0. Note:The 10th bit is not use. Value of each DIP: DIP 1 2 3 4 6 7 8 9 Value 1 2 4 8 3 2 6 4 128 256 Example 1:Set to 38 Set the 6th,3rd,1st bit of the DIP switch to“1”,others set to“0”,then the sum of the 1~9 is 32+4+1,then add 1 to it,is the start address 38. That is:[32 + 4 + 1] + 1 = 38 Example 2:Set to 226 Set the 8th,7th,6th,1st bit to “1”,others set to“0”,then the sum of the 1~9 is 128+64+32+1,then add 1 to it,is the start address 226. WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 6. That is:[128 + 64 + 32 + 1] + 1 = 226 The contents about the product install and usage Principle: (1)The input voltage should be limited in rated range. (2)Do not use it by over load. (3)Installed in suited environment. A. The driver cannot be setting in high temperature or wet conditions B. We recommend three ways to take away the heat as follows ①Bared in moving air ②Put in a big enough space for taking away the heat ③Fixed on big metalline board, and make sure they are contacted well The contents about install and usage (1)When work with controller, put the controller close to avoid the signal become weak. (2)Recommend to use the STP with the characteristic impedance of 120 ohm (3)The signal line should be one bus, and the signal line pass in and out the decoder ports directly (4)Make sure the signal line connector and the decoder's signal port are well connect (5)Add a signal terminator at the end of the signal line (6)The decoder should be closed to the lamps. If the lamps are over 5 meters, the ones follow should be joined at the decoder's out port again (7)Adopt thicker power cable with good conductibility (8)If one decoder takes several lamps in series, make sure the limps’ connectors are firmly connected (9)Signal line should be far away with the 110/220V AC cable Install Cases: (In attached drawing, the unconscionable of install cases were labeled by "X") (1)The bad install manners of take away the heat and the right ways: the wrong of install manners the right of install manners the decoder can't be set in airtight conditions Bared in moving air WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM
  • 7. woodwork(plastic) metal ventilation well (2)The install manners with weak signal and the right ways : the signal line was linked side by side Signal line was closed to the 220/380V AC The signal line should be one bus and add a signal terminator at the end of it WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM Signal line should be far away with the 220/380V AC
  • 8. Troubleshooting Guide Problem Reason Solution 1.All the lamps were off The power wire not connected well or no output Reconnect the power wire or change a power supply Lamp's power wire not connected well Reconnect the power wire Signal terminal not connected well or the signal wires were reverse Reconnect the signal cable Line is too long, for over 300m Add terminator or amplifier 2.One or several lamps not change Signal terminal not connected well or the signal wires were reverse Reconnect the signal cable Line is too long, for over 300m Add terminator or amplifier 3.Some color was off Wire of this color not connected well Reconnect the power wire 4.Wrong color was shining in change Power wire were reverse Reconnect the power wire Decoder address was wrong Change the address (refer to the address table) 5.Irregular flicker Signal terminal not connected well Reconnect the signal terminal Line is too long, for over 300m Add terminator or amplifier If still cannot figure out, please contact our technician. Orient Lighting Co., Limited is a LED products supplier and professional lighting solution provider. With years experience, We have set up one Modern LED Factory, comprehensive Research & Development base and also administration office located in exciting city Shanghai. Instant smooth communication, short production period, solid business cooperation with world class logistic network, long term warranty, sure you will be brighter & colorful by us. WWW.ORIENTLIGHTING.COM TEL: +61 (02) 80037527 EMAIL: INFO@ORIENTLIGHTING.COM